Terminal type: Exposed-lead Models.
Protective tubing diameter D: 4.8 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M: 8m E5CN-HR2H03D-FLK PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
E5CN-HR2H03D-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 48mm E5CN-HR2H03D-FLK PDF.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: - E5CN-HR2H03D-FLK PDF.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15 OMRON Basic Type. 2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), thhe transmission output,
Remote SP input function, support for a variety of applications E5CN-HR2H03D-FLK Manual.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer OMRON Basic Type.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication OMRON Basic Type. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtther performance improvement E5CN-HR2H03D-FLK Basic Type.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-HR2H03D-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.