LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTR2D Basic Type (Basic Type) PDF

OMRON E5CN-HTR2D Basic Type (Basic Type) PDF

Brand: OMRON
Product model: E5CN-HTR2D
Name: E5CN-HTR2D Manual OMRON E5CN-HTR2D Basic Type Basic Type
Sort: Basic Type (Basic Type)
File language: English
File size: 6.14MB
Size: M12 (Brass); Double; Shielded (See note 2.).
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN E5CN-HTR2D PDF.
Operation mode NO.
A new generation in global applications. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver) E5CN-HTR2D
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: - E5CN-HTR2D PDF.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5CN-HTR2D PDF.
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV OMRON Basic Type.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting functioon can predict the fault of the internal relay of the temperature controller OMRON Basic Type E5CN-HTR2D Manual. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater OMRON Basic Type.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CN-HTR2D Basic Type.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5CN-HTR2D Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
High performance temperature controller
E5CN-HR2H03-FLK
OMRON High performance temperature controller E5CN-HR2H03-FLK
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
Foundation type temperature controller
E5CN-CQ2BT
OMRON Foundation type temperature controller E5CN-CQ2BT
The main ody: terminal type, temperature inp
OMRON
High performance temperature controller
E5CN-HC2BF
OMRON High performance temperature controller E5CN-HC2BF
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HR2H01-FLK
OMRON High performance temperature controller E5CN-HR2H01-FLK
Size: 48 x 48mm. Body: terminal type. Categor