Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m E5EC-CC4ASM-005 PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
E5EC-CC4ASM-005
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EC-CC4ASM-005 PDF. Appearance: Vertical type.
Sensing method: Convergent reflective type.
Sensing distance: 2 to 5 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Accurately detects objects placed in,
front of shiny Background.
A shiny background can be used as long as the distance between,
the sensor and the background is 20 mm or more E5EC-CC4ASM-005 PDF.
Detects minute objects such as a 0.05-mm-dia. pure copper wire.
Small dispersion in sensing distance.
Light modulation effectively reduces external light interference.
Wide operating voltage range: 5 to 24 VDC. Protective tubing length L: 75cm OMRON lnstruction Manual.
Protective tubing diameter: D = 6.4.
L2: 700 mm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON lnstruction Manual.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according too the type and shape of the terminal E5EC-CC4ASM-005 Manual. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode OMRON lnstruction Manual.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makees the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EC-CC4ASM-005 lnstruction Manual.
Through the infrared port can be carried out from the frront of the communication E5EC-CC4ASM-005 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.