LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-HAA2HH01B-FLK Basic Type PDF

OMRON E5EN-HAA2HH01B-FLK Basic Type PDF

Brand: OMRON
Product model: E5EN-HAA2HH01B-FLK
Name: OMRON E5EN-HAA2HH01B-FLK Manual E5EN-HAA2HH01B-FLK Basic Type
Sort: Basic Type
File language: English
File size: 6.25MB
Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation E5EN-HAA2HH01B-FLK PDF. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling E5EN-HAA2HH01B-FLK
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products E5EN-HAA2HH01B-FLK PDF.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5EN-HAA2HH01B-FLK PDF.
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5EN-HAA2HH01B-FLK Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON Basic Type.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultThe main body: terminal type, temperature input type OMRON Basic Type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON Basic Type.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further peerformance improvement E5EN-HAA2HH01B-FLK Basic Type.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5EN-HAA2HH01B-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
High performance temperature controller
E5EN-HAA2HHBBF
OMRON High performance temperature controller E5EN-HAA2HHBBF
Size: 48 x 96mm. Category: power AC100 240V
OMRON
High performance temperature controller
E5EN-HAA2HH01BFD-FLK
OMRON High performance temperature controller E5EN-HAA2HH01BFD-FLK
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
High performance temperature controller
E5EN-HAA2HH01BD-FLK
OMRON High performance temperature controller E5EN-HAA2HH01BD-FLK
Size: 48 x 96mm. Type: power AC/DC24V with. S