Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M12 connector.
Body material: Brass.
Thread length (overall length): 27 (43).
Output configuration: PNP E5EN-HAA2HH03B-FLK PDF.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated
E5EN-HAA2HH03B-FLK
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5EN-HAA2HH03B-FLK PDF.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5EN-HAA2HH03B-FLK PDF.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON Basic Type.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermoostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-HAA2HH03B-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON Basic Type. Appearance: Flat Unshielded.
Sensing distance: 10 mm.
Output configuration: DC 3-wire NPN.
Model/Operation mode: NC.
Flat Capacitive Sensor with a.
Thickness of Only 10 mm.
Flat Sensor with excellent space efficiency.
(Model with built-in Amplifier is only 10 mm thick OMRON Basic Type. )
Direct mounting onto a metallic surface is possible. Control output: Linear current output *1.
Auxiliary output: Two.
Communications: --.
Heater burnot: Detection for Single-phase heater.
Event inputs: One.
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
Highh-speed sampling at 50 ms for applications with high-speed,
temperature increases E5EN-HAA2HH03B-FLK Basic Type.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
commplete basic functions E5EN-HAA2HH03B-FLK Manual.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.