Sensing method: Through-beam type.
Sensing distance(slot width): 3.6 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Cable length: 1 m E5ER-CT3DW-FLK PDF.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator
E5ER-CT3DW-FLK Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover) E5ER-CT3DW-FLK PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E5ER-CT3DW-FLK PDF. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance OMRON User's Manual.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set OMRON User's Manual.
It can be easily set by CS-Thermo (sold separately). E32-TC200A type: standard type; standard,
Specialty: M3 screws ((small),
Shape / detection distance (mm): 900; 680; 450 (180),
Bending radius (mm): R25 E5ER-CT3DW-FLK Manual.
Standard test object (minimum test object) (mm) 1: 1 (0 OMRON User's Manual. 006),
Fiber element for meeting diversified needsSize: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of thhe thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5ER-CT3DW-FLK User's Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5ER-CT3DW-FLK Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.