Ontology: program type.
Size: 48 x 96mm.
Type: 2 input type.
Control mode: 2 channel standard control /1 channel heating and cooling control /1 channel series control and other functions.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 2 points.
Event entry point: 4.
Serial communication: RS-485.
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.
Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON E5ER-TCT3DW-FLK.
Event entry point: 4
E5ER-TCT3DW-FLK
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV OMRON E5ER-TCT3DW-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc OMRON E5ER-TCT3DW-FLK. , can be a key operation. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increassed,
Further performance improvement E5ER-TCT3DW-FLK.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5ER-TCT3DW-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.