Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA GRT1-DRT PDF.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm).
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series. Number of phases: Three-phase
GRT1-DRT
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 15 A, 100 to 240 VAC GRT1-DRT PDF.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks GRT1-DRT PDF.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track GRT1-DRT Manual.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Global standard size,
low profile slim I/O relay with width 6 OMRON INSTRUCTIONS REFERENCE MANUAL. 2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals OMRON INSTRUCTIONS REFERENCE MANUAL.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs OMRON INSTRUCTIONS REFERENCE MANUAL.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes GRT1-DRT INSTRUCTIONS REFERENCE MANUAL.
Applicable output load(See note 2.): 75 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor efffectively absorbs external surges GRT1-DRT Manual.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.