Type: output module.
Insulation: photo coupler.
Action indicator: there.
Zero trigger function: No.
Applicable load of output: DC48 1A ~ 200V.
Input rated voltage: DC24V GX-ID3228 PDF.
I/O solid state relay can be used for OMRON I/O type G7TC relay terminal.
Input and output composite input module, the output module is complete.
Can be used for I/O type P7TF terminal. Can also be mixed with the I/O type G7T relay
GX-ID3228
Can check the working status of SSR through the action indicator.
Have access to UL, CSA standard certification of the series of products have also been series (-US type)Small, highly sensitive 1 pole signal relay GX-ID3228 PDF.
Small size 12.5 (L) * 7.5 (W) * 10 (H) mm.
Wide range of contact switch area 1mA ~ 1A.
High sensitivity coil 150mW.
Plastic sealed type, excellent environmental performance.
Coil contact between the Part68 FCC standard. (1500V, 10 * 160 s)Type: output module.
Insulation: photo coupler GX-ID3228 PDF.
Zero crossing function: No.
Action display lamp.
Output rated voltage: AC100 3A ~ 240V.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O soolid state relay GX-ID3228 Manual.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish OMRON INSTRUCTION MANUAL.
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V. Cable with connector (1 to 2) /G79-I_-_-D1,
G79-O_-_-D1, G79-M_-_-D1.
Size: A, 750mm; B, 500mm.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable OMRON INSTRUCTION MANUAL. Structure: single stable type.
Contact structure: 1a.
Structure: high flux protection.
Coil rated voltage: DC5V.
Voltage resistant 10kV 1 pole 3A open close small relay.
High power electromagnetic loop is used to achieve high sensitivity (200mW) OMRON INSTRUCTION MANUAL.
Small relays, but can ensure the impact resistance of 10kV. A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burrnout of 3-phase heaters GX-ID3228 INSTRUCTION MANUAL.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) GX-ID3228 Manual.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.