Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes GX-MD1618 PDF.
Type: Screw mounting.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting
GX-MD1618
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available GX-MD1618 PDF.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output load(See note 2 GX-MD1618 PDF. ): 90 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor effectively absorbs external surges.
Operation indicator enables monitoring operation.
Protective cover for greeater safety OMRON INSTRUCTION MANUAL GX-MD1618 Manual.
Certified by UL, CSA and TÜV.Isolation: Phototriac Coupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 5 A at 24 to 240 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A OMRON INSTRUCTION MANUAL.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation OMRON INSTRUCTION MANUAL.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Number of elements: 3.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuit input).
Applicable motor: 2.2 kW (5.5 A), 380 to 400 VAC.
Soft-start/stop Function Starts and Stops.
Three--phase Motors Smoothly and GX-MD1618 INSTRUCTION MANUAL.
Economically.
Function like an inverter by holding down the starting current.
Comply with UL, CSA, IEC (400-V models only), and JEM.
requirements.
Mount with screws or to DIN tracks.
Compact monobloock construction for the G3J-T217BL GX-MD1618 Manual.
(W: 100 × H: 100 × D: 110 mm) with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.