LK166
Home >> Download >> OMRON >> Manual Download >> OMRON H7CX-A4SD Communications Manual PDF

OMRON H7CX-A4SD Communications Manual PDF

Brand: OMRON
Product model: H7CX-A4SD
Name: Digital Controllers
Sort: Communications Manual
File language: English
File size: 2.68MB
Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0 H7CX-A4SD PDF. 1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H7CX-A4SD PDF H7CX-A4SD
External connections: 11-pin socket.
Input: Signal, Reset, Gate ((NPN/PNP input) H7CX-A4SD Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0 H7CX-A4SD PDF. 1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 OMRON Communications Manual.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input) OMRON Communications Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Supply voltage: 12 VDC.
Control output: Contact output, SPDT (time-limit SPDT).

Four-mode Timer H7CX-A4SD Communications Manual.
Multiple time ranges and operating modes let you cover a wide,
range of applications OMRON Communications Manual.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT ooutput contacts using a switch H7CX-A4SD Manual.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M.
Related products
OMRON
Multifunction Counter/Tachometer
H7CX-A4-N
OMRON Multifunction Counter/Tachometer H7CX-A4-N
Type: H7CX-A Series. Classification: Preset
OMRON
Multifunction Counter/Tachometer
H7CX-A11S-N
OMRON Multifunction Counter/Tachometer H7CX-A11S-N
Type: H7CX-A Series. Classification: Preset
OMRON
Multifunction Counter/Tachometer
H7CX-AWSD1-N
OMRON Multifunction Counter/Tachometer H7CX-AWSD1-N
Type: H7CX-A Series. Classification: Preset
OMRON
Multifunction Counter/Tachometer
H7CX-AW-N
OMRON Multifunction Counter/Tachometer H7CX-AW-N
Type: H7CX-A Series. Classification: Preset