LK166
Home >> Download >> OMRON >> Manual Download >> OMRON K2CM-1L Communications Manual PDF

OMRON K2CM-1L Communications Manual PDF

Brand: OMRON
Product model: K2CM-1L
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 0.29MB
Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V K2CM-1L PDF.
Rated frequency: 50/60Hz.
Voltage adjustment range: 115-120-125-130-135-140-145-150V (8 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA K2CM-1L
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-160V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1 K2CM-1L PDF. 5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shunt,
Easy to coordinate digital VR.
And the automatic tester with convenient for relay testing.
Measurable voltaage value K2CM-1L Manual.
The reliability can be improved by monitoring the function at any time.
The forced action of the experimental switch can be easily recognized K2CM-1L PDF.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except). Applicable Current Transformer.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON Communications Manual.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON Communications Manual.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Compact and Slim Relay Ideal for OMRON Communications Manual.
Temperature Alarms and Moonitoring K2CM-1L Communications Manual.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-inpput support for thermocouple or Pt100 sensor input K2CM-1L Manual.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator.
Related products
OMRON
Heater Element Burnout Detector
K2CU-F80A-FGS
OMRON Heater Element Burnout Detector K2CU-F80A-FGS
Control supply voltage: 220 VAC With voltage
OMRON
Heater Element Burnout Detector
K2CU-F40A-E
OMRON Heater Element Burnout Detector K2CU-F40A-E
Control supply voltage: 200 VAC With voltage
OMRON
Over current relay
K2CA-DO-R2
OMRON Over current relay K2CA-DO-R2
Appearance: there are F4 shell, R2 shell. Cir
OMRON
Heater Element Burnout Detector
K2CU-P0.5A-A
OMRON Heater Element Burnout Detector K2CU-P0.5A-A
Control supply voltage: 100/200 VAC With vol