File size: 2.07MB
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay K3HB-HTA-FLK3AT11 PDF.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported K3HB-HTA-FLK3AT11
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Input type: DC voltage input type.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL) K3HB-HTA-FLK3AT11 PDF.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-HTA-FLK3AT11 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations OMRON Communications Manual.
DeviSetting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents OMRON Communications Manual.
Use commercially available CTs (CT current on secondary,,
side: 0 to 1 A or 0 to 5 A) K3HB-HTA-FLK3AT11 Manual.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load) OMRON Communications Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Models: OVGR (64).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributtaries K3HB-HTA-FLK3AT11 Communications Manual.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K3HB-HTA-FLK3AT11 Manual.
2 stage cross terminal stand with cover with convenient wiring.
Related products
OMRON
Temperature panel
K3HB-HTA-FLK1AT11 AC100-240
OMRON Temperature panel K3HB-HTA-FLK1AT11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-T11 AC100-240
OMRON Temperature panel K3HB-HTA-T11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Temperature panel
K3HB-HTA-L2AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-L2AT11 AC/DC24
Type of input: platinum resistance / thermoco