Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase) K3HB-SSD-CPAC21 PDF.
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods
K3HB-SSD-CPAC21
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-SSD-CPAC21 PDF.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2 K3HB-SSD-CPAC21 PDF.
CE marking and cUL certified (K8AC-H2@@@). Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply vvoltage: 100 to 240 VAC K3HB-SSD-CPAC21 Manual.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously OMRON User's Manual.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load) OMRON User's Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON User's Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K3HB-SSD-CPAC21 User's Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-SSD-CPAC21 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.