Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Fixed phase Asymmetry monitoring.
Prevents reverse motor rotation due to incorrect wiring K3HB-VLC-L1BT11 PDF.
Distinguishes between positive phases, reversed phases, and phase,
loss when power is turned ON.
Voltage detection method enables application for any load current.
One SPDT output relay, 6 A at 250 VAC (resistive load)
K3HB-VLC-L1BT11
Output status can be monitored using LED indicator. Power supply voltage: 100 to 240 VAC.
Type: Temperature input.
Output relays: 1 relay.
Input types: Thermocouple or platinum resistance thermometer K3HB-VLC-L1BT11 PDF.
Setting units (setting range): Setting unit: 1°C or 1°F (0 to 999°C/°F).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22 K3HB-VLC-L1BT11 PDF. 5 mm.
Rotary switches simplifies temperature settings.
Universal-input support for thermocouple or platinum,
resistance thermometer sensor input.
Change the output relay between normally open and,
normally closed operation.
Alarm status identification with LED iindicator OMRON User's Manual K3HB-VLC-L1BT11 Manual.
Self-holding output.
Alarm output status can be retained even if the power,
supply is turned OFF. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input OMRON User's Manual.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON User's Manual.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable fromMeasuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically ressetting supported by one Relay K3HB-VLC-L1BT11 User's Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-VLC-L1BT11 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.