Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC K3HB-XAD-FLK1AT11 PDF.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model.)
High-performance Power Monitor Suitable for On-panel Mounting and Display
K3HB-XAD-FLK1AT11
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported K3HB-XAD-FLK1AT11 PDF. )
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive ppower, lagging reactive power, and consumed power K3HB-XAD-FLK1AT11 PDF K3HB-XAD-FLK1AT11 Manual.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power OMRON Communications Manual. )
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage OMRON Communications Manual.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Type: related equipment (sold separately); split type current transformer (CT).
Rated primary side current: 100A.
Rated two secondary current: 1A.
Simple monitoring of the use of electricity to support energy saving countermeasures OMRON Communications Manual.
On behalf of the use of the mechanical equipment, the measurement of thhe initial voltage, current,
Cumulative quantity, invalid power, power factor, frequency K3HB-XAD-FLK1AT11 Communications Manual.
To achieve a simple record with a memory card. (with memory card function model)
The measurement data can be stored in the main body, and the centralized monitoring and management can be carried out in the communication network K3HB-XAD-FLK1AT11 Manual.
Wide 45mm miniaturization, simple set to the DIN guide.