Static ground directional relay K2GS-B type,
Advanced ground direction relay corresponding to the diversification of ground fault.
Feeder priority cut-off function for coordinated multi segment setting K3HB-XVD-CPAC11 PDF.
Prevention of low frequency vibration with other circuit accidents,
Circuit for locking circuit and preventing effect of electric wave caused by false action,
In order to improve the reliability
K3HB-XVD-CPAC11
The coordination device for the zero phase action voltage is set up,
Therefore, the influence of the residual voltage can be avoided.
Due to the built-in filter, so in the event of the occurrence of the ramp wave input can also maintain a stable role,
Because of the signal level detection, it is easy to carry out the action experiment and set up the confirmation K3HB-XVD-CPAC11 PDF. Measuring current: 10 to 100 A AC, 20 to 200 A (See note.).
Supply voltage: 200-230 VAC.
Ideal for current monitoring for,
industrial facilities and equipment K3HB-XVD-CPAC11 PDF.
Monitor for overcurrents or undercurrents. K3HB-XVD-CPAC11 Manual.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed OMRON Communications Manual.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control OMRON Communications Manual.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods OMRON Communications Manual.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase ccontrol, and cyclic control K3HB-XVD-CPAC11 Communications Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-XVD-CPAC11 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).