Description: OS32C with side location cable entry.
Max. Operating Range (Safety Zone): 4m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23 OMRON SYSMAC CV-Series ISA Control System Operation Manual PDF
OMRON SYSMAC CV-Series ISA Control System Operation Manual
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments OMRON SYSMAC CV-Series ISA Control System Operation Manual PDF.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 500 or 70 mm OMRON SYSMAC CV-Series ISA Control System Operation Manual Manual.
The response time is configurable from 80 ms to a maximum of 680 ms OMRON SYSMAC CV-Series ISA Control System Operation Manual PDF.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram OMRON SETUP MANUAL. Description: OS32C with EtherNet/IP and side location cable entry.
Max. Operating Range (Safety Zone): 3m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23 OMRON SETUP MANUAL.
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3 OMRON SETUP MANUAL.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments.
A safety radius up to 4 m and warning zone(s) radius up to 115 m can be set OMRON SYSMAC CV-Series ISA Control System Operation Manual SETUP MANUAL.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitooring function prevents unauthorized changes in,
the scanner position OMRON SYSMAC CV-Series ISA Control System Operation Manual Manual.
Minimal down time, sensor block can be replaced without the need to reprogram.