Description: OS32C with back location cable entry.
Max. Operating Range (Safety Zone): 4m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23 OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference PDF
OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference PDF.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference Manual.
The response time is configurable from 80 ms to a maximum of 680 ms OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference PDF.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram OMRON USER'S MANUAL. Description: OS32C with side location cable entry.
Max. Operating Range (Safety Zone): 3m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23 OMRON USER'S MANUAL.
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3 OMRON USER'S MANUAL.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be sett OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference USER'S MANUAL.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitooring function prevents unauthorized changes in,
the scanner position OMRON Smart Sensors ZS Series CompoWay/F Communication Command Reference Manual.
Minimal down time, sensor block can be replaced without the need to reprogram.