Power rating: 75 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 12 V VDC.
Output current: 6 S3200-CN102-25-25 PDF. 2 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
S3200-CN102-25-25
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty S3200-CN102-25-25 PDF.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately) S3200-CN102-25-25 PDF.
Refer to Period and Terms of W. BatteryBatteryTerminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 24 VDC.
Overcurrent detection: Inverse type.
Soliid-state, Plug-in Current Sensor S3200-CN102-25-25 Manual.
Applicable to motor overcurrent protection and 3-phase AC current detection OMRON PROGRAMMING MANUAL.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available.
Instantaneous type under current sensor available.
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Type: open type OMRON PROGRAMMING MANUAL.
Structure: bottom mounting type.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function OMRON PROGRAMMING MANUAL.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support fiinger touch protection to prevent electric shock S3200-CN102-25-25 PROGRAMMING MANUAL.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer S3200-CN102-25-25 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)