Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 100W.
Output voltage: 48VDC S3200-CN152-62-62 PDF.
Output current: 2.3A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time
S3200-CN152-62-62 Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V S3200-CN152-62-62 PDF.
Output current: 3.75 A.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards S3200-CN152-62-62 PDF.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment displlay S3200-CN152-62-62 Manual.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON PROGRAMMING MANUAL.
(Not compliant with EC Directives and other safety standards.) Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Alarm output: leakage type OMRON PROGRAMMING MANUAL.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity OMRON PROGRAMMING MANUAL.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support fiinger touch protection to prevent electric shock S3200-CN152-62-62 PROGRAMMING MANUAL.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer S3200-CN152-62-62 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"