Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC S8EX-BP10012LC PDF.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices
S8EX-BP10012LC
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-proof,
construction (IP67) enables direct on-site,
mounting S8EX-BP10012LC PDF.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (8-point models).
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal S8EX-BP10012LC PDF.
System Configuration. Output voltage: 12 V.
Output current: 2.5 A.
CConnector terminal Model (See note 3 S8EX-BP10012LC Manual. ): Without Bus Line Connectors (See note 2.).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail OMRON Connection Guide.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels).
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models) OMRON Connection Guide.
RoHS-compliant.
Input conditions: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable.)
Operating temperatures to –20°C (24-V models). Appearance: insert type.
Control supply voltage: DC100/110V.
Action elements: overload detection OMRON Connection Guide.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock time, iinstantaneous action, etc S8EX-BP10012LC Connection Guide. , are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT orr the relay part is not needed, and the use is simple S8EX-BP10012LC Manual.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple.