Output voltage: 5 V.
Output current: 5 A.
Screw terminal Model: Without Bus Line (See note 2.).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail S8VS-01512 PDF.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels)
S8VS-01512
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models).
RoHS-compliant.
Input conditions: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable S8VS-01512 PDF. )
Operating temperatures to –20°C (24-V models). Power rating: 150 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 48 V VDC.
Output current: 3.3 A.
Built-in fan: None S8VS-01512 PDF.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surgge resistance for stable,
operation even with an unstable input voltage OMRON Installation and Operating Manual S8VS-01512 Manual.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON Installation and Operating Manual.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 0 OMRON Installation and Operating Manual. 2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Avaailable in 7 supply voltage configurations S8VS-01512 Installation and Operating Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection S8VS-01512 Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).