LK166
Home >> Download >> OMRON >> Manual Download >> OMRON S8VS-09024 Installation and Operating Manual PDF

OMRON S8VS-09024 Installation and Operating Manual PDF

Brand: OMRON
Product model: S8VS-09024
Name: Vision Sensor
Sort: Installation and Operating Manual
File language: English
File size: 0.80MB
Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 20 A S8VS-09024 PDF.
Number of output branches: 8 branch outputs.
Communications functions: None.
Parameter settings: Changeable.
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digital circuit,
protectors in a single package S8VS-09024
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature) S8VS-09024 PDF.
Conforms to UL Class 2.
Mounts to DIN Rail. Appearance: insert type.
Control supply voltage: AC200/220/240V.
Action elements: overload detection.
Action characteristic: lock, instant action type.
Especially suitable for single phase motor over current protection S8VS-09024 PDF.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti time limit characteristics, lock time, instantaneous action, etc., are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual siituation OMRON Installation and Operating Manual S8VS-09024 Manual.
When the current is large, the input resistance of the CT or the relay part is not needed, and the use is simple.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple. Category: incidental cover type OMRON Installation and Operating Manual.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 30W.
Output voltage: 5V.
Output current: 6A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON Installation and Operating Manual.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Suppoort finger touch protection to prevent electric shock S8VS-09024 Installation and Operating Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer S8VS-09024 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Related products
OMRON
Switch Mode Power Supply
S8VS-24024
OMRON Switch Mode Power Supply S8VS-24024
Power ratings: 240 W. Input voltage: 100 to
OMRON
Switch Mode Power Supply
S8VS-12024B-F
OMRON Switch Mode Power Supply S8VS-12024B-F
Power ratings: 120 W. Input voltage: 100 to
OMRON
Switch Mode Power Supply
S8VS-06024
OMRON Switch Mode Power Supply S8VS-06024
Power ratings: 60 W. Input voltage: 100 to 2
OMRON
Switch Mode Power Supply
S8VS-24024AP
OMRON Switch Mode Power Supply S8VS-24024AP
Power ratings: 240 W. Input voltage: 100 to