Memory card interface, serial interface.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by sttep A73CPU-S3.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be A73CPU-S3.
Special multi axis positioning controller for NSD servo system.
Program capacity: Max 60K step.
Input / output points: 1920 points.
Control AC motor required I/O points with PLC control AC motor,
Signal and feedback signal is used as the input signal of PLC,
The control of AC motor is accomplished by using the output signal of PLC to drive the contactor A73CPU-S3.
For example, the AC motor is controlled by a Y- delta starting with PLC,
Generally need to occupy 4 of the PLC input and 3 output points,
PLC control of a one-way operation of the cage type motor,
4 input points and 1 output points are occupied, and a reversible motor is controlled,
5 input points and 2 output points are needed to control a unidirectional operation of variable pole speed control motor,
5 input points and 2 output points are required to control a unidirectional operation of the rotor AC motor,
3 input points and 4 output points are needed to control a reversible running winding rotor AC motor,
Requires 4 input points and 5 output points MITSUBISHI A73CPU-S3 MITSUBISHI A73CPU-S3. Output points: 8 points.
Output voltage and current: DC12/24V, 0.1A/1 point, 0 MITSUBISHI A73CPU-S3.8A/1 common end.
Response time: 2ms.
8 point /1 a public side.
Output form: transistor output, leakage type.
26 point terminal station.
Number of stations: 1 stops.
Type remote I/O unit (twisted pair data connection).
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved.
Q series PLC in the use of CC-Link function better,
And easier to use.
Mitsubishi Co PLC network inherited the traditional use of the MELSEC network,
And make it better in terms of performance, function, easy to use etc..
Provides a layer of three layers of clear network, to provide the most suitable network products for a variety of uses.
The information layer /Ethernet (Ethernet) information layer is the highest level of the network system,
Mainly in the PLC, the device controller and production management with PC transmission between production management information, quality management information and the operation of equipment, etc.,
Information layer using the most common Ethernet.
It is not only able to connect the PC system UNIX, windows system, etc.,
And can connect a variety of FA devices.
The Ethernet module has the function of Internet e-mail receiving and sending,
The user can send and receive the production information conveniently iin any place of the world,
Build a remote monitoring management system A73CPU-S3.
At the same time, the use of the Internet FTP server functions and MELSEC protocol can be very easy to achieve the program upload / download and transfer of information.