LK166
Home >> Supply >> A960GOT-EBA-EU Power supply: AC100-240V MITSUBISHI A960GOT-EBA-EU 9 inch man machine interface
Search
Information sort

A960GOT-EBA-EU Power supply: AC100-240V MITSUBISHI A960GOT-EBA-EU 9 inch man machine interface


Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 16 points.
Output voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output response time: 2ms.
16 point /1 a public side A960GOT-EBA-EU.
Output type: transistor ooutput (type sink).
With the surge absorber.
50 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A960GOT-EBA-EU.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A960GOT-EBA-EU.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points MITSUBISHI A960GOT-EBA-EU.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI A960GOT-EBA-EU.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI A960GOT-EBA-EU. Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:1.0.
Optical data communication line.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Series Name: A960GOT.
Size: 9 inches.
Resolution: 600 * 400.
Display device: high brightness EL.
Display color: color (black, orange).
Power supply: AC100-240V.
Memory card: 1M.
Authentication: UL/cUL/CE.
Human computer interaction is the interaction between human and machine, which is essentially human and computer.
Or from a broader perspective: human computer interaction is the interaction between people and machines that contain computers.
Specifically, the two-way communication between the user and the computer machine,
Using a certain symbol and a liquid crystal screen to be used as a man-machine interface display
Action to achieve, such as the hit key, move the mouse, display the symbol / graphics on the screen, etc..
This process consists of several sub processes: identifying the interaction object, understanding the interaction object, grasping the object modality, information adaptation and feedback, etc.;
The human computer interface is the communication media or means between the user and the computer system containing the computer,
The support software and hardware of the two-way information exchhange between human and computer A960GOT-EBA-EU. The interface is defined as the media or means of communication,
Its physical and chemical embodiment is related to the support of software and hardware, such as a graphical display terminal with the mouse, etc..

Related supply information