For 3-slot Backplane.Model: C200H-MR833.
Description: RAM, 8K words, battery back-up.with clock(CPU21, CPU23 only).
Name: Temperature Sensor Module.
Model: C200H-TS102.
Temperature sensor: RTD (Pt 100 Ω.)(DIN/1989 JIS).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected) C200H-TS102.Model: C200H-AD003.
Input points: 8.
Volttage input: 1 to 5 V, 0 to 10 V, or –10 to 10 V.
Current input: 4 to 20 mA.Unit type: CS1 CPU Bus Unit.
Product name:SPU Unit,
(High-speed Data Storage Unit) C200H-TS102.
Specifications: PC Card slot,
1 PC Card Type II slot Insert an,
OMRON HMC-EF@@@ to use the Memory Card;
Ethernet (LAN) port, 1 port(10/100BASE-TX).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.56A; 26V, --.
Standards: UC1, CE C200H-TS102.
High-speed Collection of System Data.
The CPU Unit can collect large amounts,
of process data, operation data,
inspection data, and other controlled system,
data quickly and automatically save the data,
in external storage media as CSV files OMRON C200H-TS102. Model: C200H-DA001.
Input points: 2.
Voltage input: 1 to 5V or 0 to 10 V.
Current input: 4 to 20 mA.CPU Bus Cable (Expansion CPU Rack) 0.6 m (L) CV500-CN611Includes text book, cassette tape, and input switch board.Model : CVM1D-PA208.
8A.
Attach two things in the same format in each base Please you OMRON C200H-TS102.I/O Cable (for I/O to Interface Racks) 30 m (L) CV500-CN322100 to 120/200 to 240 VAC (switchable), Wired.CPU Unit: CP1L-M CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 18; Output, 12 OMRON C200H-TS102.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C200H-TS102.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.