CPU Unit: CP1L-EM CPU Units with 30 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sinking);
Inputs, 18; Output, 12 C200HE-CPU42-ZE.
Standards: CE.
High Perforrming Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port C200HE-CPU42-ZE.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Model: CPM2A-60CDT-D. Power supply: DC power supply.
Output type: Transistor sinking.
Inputs points: 36 points.
Outputs points: 24 points C200HE-CPU42-ZE.
UM: 7.2K words.
DM: 6K words.
EM: --.
Instruction processing time (basic instructions): 0.3 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable OMRON C200HE-CPU42-ZE.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.CPU Unit: CP1L-EL CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output(sourcing);
Inputs, 12; Output, 8 OMRON C200HE-CPU42-ZE.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port OMRON C200HE-CPU42-ZE.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. C500-CT Special I/O Unit High-speed Counter Unit 20 kcps 4 pts C500-CT041.CV500-FH SYSMAC BUS PC Unit Floppy/Hard Disk Drive For 200 VAC CV500-FHD02.Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C200HE-CPU42-ZE.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.