LK166
Home >> Supply >> CJ1H-CPU65H Programmable Controllers LD instruction OMRON CJ1H-CPU65H
Search
Information sort

CJ1H-CPU65H Programmable Controllers LD instruction OMRON CJ1H-CPU65H


Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming,
I/O communications: 64 nodes;
No CJ1H-CPU65H. of axes: 4 axess.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency CJ1H-CPU65H.
The EtherCAT communications with,
100Mbps baud rate enables fast,
and accurate position control.
A wide range of position control,
functions are available with,
this position control unit CJ1H-CPU65H. Output method: Analog resolution: 1/6000.
Analog Outputs: 4.
I/O capacity/Mountable Units(Expansion Racks): 2, 560 points/40 Units (3 Expansion Racks max.).
Program capacity: 60K steps.
CJ1H-CPU65H CPU Data memory capacity: 128K words(DM: 32K words, EM: 32K words × 1 bank) OMRON CJ1H-CPU65H.
LD instructionName: I/O Interface Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System,
or Single CPU System;
Duplexing, Not supported;
Online Replacement, Not supported;
Mounting Backplane,Expansion Backplane;
Connecting Cable,
Long-distance Connecting Cable OMRON CJ1H-CPU65H.
Current consumption: 5V system, 0.23A;
26V system, --.
Standards: U, C, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Power supply: DC power supply OMRON CJ1H-CPU65H.
Output method: Transistor output source type.
Inputs points: 18 points.
Outputs points: 12 points.Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CJ1H-CPU65H.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.