Model: CPM2C-8ETC. Units with relay outputs only.
1 Fujitsu connector.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Platinum , resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector,
PNP outputs (pulses) CJ1W-ID211.
No. of unit numbers allocated: 2 CJ1W-ID211.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output CJ1W-ID211.
Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 16 inputs;
Input voltage and current: 24 VDC, 7 mA;
Commons, 16 points, 1 common; External connection,
Removable terminal block; No OMRON CJ1W-ID211. of words allocated,1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit OMRON CJ1W-ID211.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 8 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max OMRON CJ1W-ID211.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. CPU Bus Cable (Expansion CPU Rack) 0.6 m (L) CV500-CN611Output method: Relay.
Inputs: 12.
Outputs: 8.For 10-slot Backplane.Unit type: CJ1 Basic I/O Units.
Product name: AC Input Units.
Specifications: I/O points, 8 inputs;
Input voltage and current: 200 to 24 VAC, 10 mA(200V, 50Hz);
Commons, 8 points, 1 common; External connection,
Removable Terminal Block; No. of words allocated, 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF siignals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit CJ1W-ID211.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
 