Product name: E@@S type CPU Units with 30 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; Outputs, 12;
Output type: Relay.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0 CJ1W-V680C12.17A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Proggrammable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CJ1W-V680C12.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Power supply: AC power supply.
Output method: Relay output.
Inputs points: 12 points.
Outputs points: 8 points CJ1W-V680C12.
Type: CJ1 Special I/O Unit.
Connected ID System: V680 Series; 2 Heads.
External power supply: --.
No. of unit numbers used: 2 unit number.
Current consumption: 5V, 0.32A;
24V, 0.26A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series OMRON CJ1W-V680C12.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes. Number of inputs: 32 pts.
Input Voltage: 24V DC OMRON CJ1W-V680C12.
Input Current: 6 mA.Model: CPM2C-24EDT1. Units with 24 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.Cover for 10-pin terminal block.
Terminal cover for 8-point or 5-point I/O Units OMRON CJ1W-V680C12.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CJ1W-V680C12.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.