Name: MIL Connectors.
Specifications: Inputs/Outputs;
16 inputs/16 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CPM1A-40CDR-A-V1.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CPM1A-40CDR-A-V1.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CJ1 Basic I/O Units OMRON CPM1A-40CDR-A-V1.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 outputs(High speed);
Maximum switching capacity, 24VDC, 0 CPM1A-40CDR-A-V1.5A;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No OMRON CPM1A-40CDR-A-V1. of words allocated: 1 word.
Current consumption: 5V, 0.15A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices OMRON CPM1A-40CDR-A-V1.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Universal
inputs: Pt100 (3-wire), JPt100 (3-wire),
Pt1000 (3-wire), Pt100 (4-wire), K, J,
T, E, L, U, N, R, S, B, WRe5-26, PL II,
4 to 20 mA, 0 to 20 mA, 1 to 5V, 0 to 1.25V,
0 to 5V, 0 to 10V, ±100 mV selectable range,
-1.25 to 1.25 V, -5 to 5 V, -10 to 10V,
±10V selectable range, potentiometer.
Conversion speed (resolution): Resolution
(conversion speed): 1/256,000 (conversion cycle:
60 ms/ 4 inputs) 1/64,000 (conversion cycle:
10 ms/4 inputs) 1/16,000 (conversion cycle:
5 ms/4 inputs).
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.30A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Anaalog Signal Inputs (e CPM1A-40CDR-A-V1.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.