LK166
Home >> Supply >> CQM1-TC101 OMRON CQM1-TC101 Temperature Control Module
Search
Information sort

CQM1-TC101 OMRON CQM1-TC101 Temperature Control Module


Connects to right-hand side of CPU block.Model: CPM2C-8ETM. Units with relay outputs only.
1 MIL connector.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Specification: Platinum resistance thermometer input (Pt, JPt),
ON/OFF or advanced PID control,
tran-sistor (NPN) output, 2 loops CQM1-TC101.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input CQM1-TC101.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A CQM1-TC101.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON CQM1-TC101.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them OMRON CQM1-TC101.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available OMRON CQM1-TC101.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Name: Temperature Control Module.
Model: C200H-TC001.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Transistor output100 to 120/200 to 240 VAC (switchable), APF/PCF.Model: C200H-AD002.
Input points: 8.
Voltage input: 1 to 5 V, 0 to 10 V, or –10 to 10 V.
Current input: 4 to 20 mA.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CQM1-TC101.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Related supply information