Name: Two-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CS1D-BC052.
A wide variety of CompooNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1D-BC052. Model: C200H-MAD01.
External input points: 2.
External output points: 2.
External input signal range: 1 to 5 V or 0 to 10 V or –10 to 10 V CS1D-BC052.
External output signal range: 1 to 5 V or 0 to 10 V or –10 to 10 V.
Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System only;
Number of Power Supply Units, 2 Units max.
(for duplex operation);
Number of I/O Units, 5 Units max OMRON CS1D-BC052.
Current consumption: 5V system, 0.55A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Model: C500-BC081(3G2A5-BC081).
8 slots(3 linkable slots) OMRON CS1D-BC052.
Specifications: Without clock (see below).C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATT83.Model: C200H-TS002.
Temperature sensor: Thermocou-ples: K (CA)/L (Fe-CuNi)(DIN)(selectable)
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected)Type: CS Special I/O Unit OMRON CS1D-BC052.
Connected ID System: V680 Series; 2 Heads.
External power supply: 24VDC.
No. of unit numbers used: 2 unit number.
Current consumption: 5V, 0.32A;
24V, --; External, 0.36A.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes. Product name: CJ-series I/O Control Unit.
Specifications: One I/O Interface Unit is,
required on each Expansion Rack.
Connecting Cable: CS1W-CN@@3 Expansion,
Connecting Cable Mount to the right of,
the Power Supply Unit.
Current consumption: 5V , 0.02A;
24V, --.
Standards: UC1, N, L, CCE CS1D-BC052.
Expand CJ/NJ-series with These Units.
To expand a CJ/NJ-series Controller,
connect an I/O Control Unit to the CPU Rack,
and I/O Interface Unit to the Expansion Rack,
and connect the two Units with I/O Expansion Cable.