Name: Temperature Sensor Module.
Model: C200H-TS102.
Temperature sensor: RTD (Pt 100 Ω.)(DIN/1989 JIS).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Product name: NA-type CPU Units with 20 I/O Points (Built-inanalog).
Specifications: Power Supply, 24 VDC; Inputs,
12(Built-inanalog inputs: 2; Outputs, 8(Built-inanalog outputs: 1;
Output type: Transistor (sinking) CS1W-DA08V.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): -- CS1W-DA08V.
Current consumption: 5 V, 0.23A; 24 V,0.09A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality CS1W-DA08V.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection.
Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point OMRON CS1W-DA08V.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0 OMRON CS1W-DA08V.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals.CPU Unit: CP1H-XA CPU Units.
Specifications: CPU type, Memory capacity: 20K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Analog inputs: 4, Analog outputs: 2;
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 24; Output, 16 OMRON CS1W-DA08V.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O. C500-OD I/O Unit TTL Output 32 pts C500-OD501CN.
DC5V 35mA.Name: Clamp Terminal Blocks.
Specifications: Outputs; 8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1W-DA08V.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.