Output method: Transistor sinking.
Inputs: 12.
Outputs: 8.8 pts, 1.2 A, 120 VAC
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1 CS1W-PPS01.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CS1W-PPS01.
Because of this, no ladder program is required,
at the CPU Unit for scaling CS1W-PPS01.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON CS1W-PPS01.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems OMRON CS1W-PPS01.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point OMRON CS1W-PPS01.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals.Output method: Transistor sinking.
Inputs: ---.
Outputs: 8.A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Unitts receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CS1W-PPS01.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
 