CS1W-PPS01 OMRON CS1W-PPS01


UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable CS1W-PPS01.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model : CVM1-CPU21-V2.
Ladder only 2, 048 (with RAM62K word, higher internal link).
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit CS1W-PPS01.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CS1W-PPS01.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON CS1W-PPS01.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems OMRON CS1W-PPS01.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring OMRON CS1W-PPS01.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Model: CPM2C-16ET1C. Units with transistor outputs only.
1 Fujitsu connector.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.100 to 120/200 to 240 VAC (switchable), Wired.Model : CV500-TDL21.
You can connect up to 64 at a temperature controller using two communication ports..Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CS1W-PPS01.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.