Actuator: Roller plunger (Metal roller).
Cable length: 1 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 2NC/2NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model) DRT2-AD04H.
High-sensitivity safety limit swittch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2 DRT2-AD04H.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: Standard.
Contact gap: 3 mm min.
Mounting: Panel mounting.
Contact form: DPST-NO.
Door Interlock Power.
Switch with Minimum.
Contact gap of 3 mm.
Offers the minimum contact gap of 3 mm required DRT2-AD04H.
for power switches as standard equipment.
Safety considerations include a double return spring,
and direct drive positive contact opening feature.
Pull-on lock model for easy maintenance is also available.
Classification: Analog input OMRON DRT2-AD04H.
I/O points: 4 inputs (Resolution: 30, 000).
Performs Calculations on Analog Values within the Slave Itself.
Also Provides High Resolution at 1/30,000 (Full Scale) and,
Support for a Wide Variety of Data Sampling.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities OMRON DRT2-AD04H.
Sampling data can be analyzed internally to provide a low-cost scheduler function.
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative,
calculation function OMRON DRT2-AD04H.
Two I/O points can be allocated to any two of the following values: analog,
input, peak/bottom, top, valley, or rate-of-change. Values without an,
allocated I/O point can be read with message communications. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
Lockout Key to prevent workers from becoming DRT2-AD04H.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.