Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N DRT2-OD08.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas DRT2-OD08.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Release Key Type: Standard (metal).
Wiring method: Terminal block DRT2-OD08.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ OMRON DRT2-OD08.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal OMRON DRT2-OD08.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller OMRON DRT2-OD08.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Specifications: Outputs; NPN (- common); 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information DRT2-OD08.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier.