LK166
Home >> Supply >> FR-F740-S220K-CHT | MITSUBISHI 3 phase 400V converter FR-F740-S220K-CHT
Search
Information sort

FR-F740-S220K-CHT | MITSUBISHI 3 phase 400V converter FR-F740-S220K-CHT


Max input / output points: 64 points.
Power supply voltage: 24VDC.
Input points: 32 points.
Output points: 32 points.
Output type: relay.
Power consumption: 35W.
Weight (kg):1.0.
Size (WxHxD) mm:220x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FR-F740-S220K-CHT.
Continuoous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017) FR-F740-S220K-CHT.
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FR-F740-S220K-CHT MITSUBISHI FR-F740-S220K-CHT MITSUBISHI FR-F740-S220K-CHT.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules MITSUBISHI FR-F740-S220K-CHT.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.75KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input ppower is large, and a large amount of energy consumption in the baffle, the valve in the process of closure FR-F740-S220K-CHT.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.

Related supply information