Can be used as a screw relay terminal.MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 11kw.
SLD converter rated current: 63A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so youu do not need to worry about the replacement operation FX2N-16CCL-M.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station FX2N-16CCL-M.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced FX2N-16CCL-M.
Master station module for CC-Link.
FX2N-16CCL-M is the PLC CC-Link as the FX master module.
Up to 7 remote I/O stations and 8 remote stations can be connected to the main station.
Using the CC-LINK FX2N-32CCL interface, you can install PLC FX as CC-LINK remote device station to connect MITSUBISHI FX2N-16CCL-M.
In addition, through the connection of various equipment manufacturers, can be applied to a variety of purposes of the system.
The most suitable for production lines and other equipment control. MITSUBISHI inverter FR-E740 series.
Voltage level: 3 phase 400V MITSUBISHI FX2N-16CCL-M.
Frequency converter capacity: 2.2KW.
Allow short-time overload (200% 3S).
The machine itself does not need to purchase another operating panel.
Provide USB interface to connect with the computer, you can use the FRConfigurator software to set the parameters of the inverter or monitor MITSUBISHI FX2N-16CCL-M.
Inverter surface with PU interface, FR-E500 operating panel can be directly connected to the E700 series. The installation dimensions are in full agreement with FR-E500.
Allow side by side installation, saving installation space
Simple maintenance: equipped with comb type wiring board, wiring more convenient, the replacement of the same series inverter, no stitches, as long as the original inverter control terminal. Input points: 24 points.
Output points: 16 points.
Power supply voltage: AC160-240V.
Output type: transistor output (drain).
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
High speed operation FX2N-16CCL-M.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.