MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of verrtical as possible FX2N-4DA.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used FX2N-4DA. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft FX2N-4DA.
Voltage input: DC-10~10V.
Current input: DC0~20mA.
Channel number: 4 channel analog output.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V) MITSUBISHI FX2N-4DA.
Resolution of 11 bit binary + symbol 1 (voltage), 10 bit binary (current) high precision analog output module.
Voltage output and current output of 4 channels can be carried out.
Can be specified for each channel voltage or current output. Expansion board for connection to a special adapter MITSUBISHI FX2N-4DA.Max input / output points: 32 points.
Supply voltage: 100 - 240VAC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (sinktype).
Power consumption: 35W.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x86.
Faster and more efficient MITSUBISHI FX2N-4DA. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system.
Third generation high function micrro programmable controller FX2N-4DA.
High speed, high efficiency, high performance, large capacity, and new features.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points.