Temperature measurement resistor input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode LY20S6-CM.
Achieve average temperatture control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion LY20S6-CM.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time MITSUBISHI LY20S6-CM.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming LY20S6-CM.
It is very effective to use the control object that does not want to heat up to the time of arrival error MITSUBISHI LY20S6-CM.
Applicable to a variety of systems.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch.
Equipped with temperature input mode.
The temperature control module can be used as a temperature input module.
By setting the switch, you can easily change the input mode MITSUBISHI LY20S6-CM. Cable length: 1.0m.
Weight: 0.23kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conductor of electricity or information from one place to another.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover.
The cable has the characteristics of internal power and external insulation. Number of input channels: 2Ch.
Input voltage: DC - 10 ~ 10V.
Input current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Output channel number: 2Ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 80 s/ch.
Resolution: 1/12000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period LY20S6-CM.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.