LK166
Home >> Supply >> OMRON 3G2A5-AD003 OMRON 3G2A5-AD003
Search
Information sort

OMRON 3G2A5-AD003 OMRON 3G2A5-AD003


JX / MX / RX seriesSpecification: three phase 400V.
Power: 90KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 89 kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more exttensive 3G2A5-AD003.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV 3G2A5-AD003.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function 3G2A5-AD003.
Inverter input power: 3 phase / single phase AC200V.
Weight: 0.8KG.
Standard applicable line diameter: 1.25 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor OMRON 3G2A5-AD003. Box protection class: plastic, IP00.
Terminal size: M5.
Line diameter: 14 square mm.
Weight: 1.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line OMRON 3G2A5-AD003.
Try to be close to the transducer for connection. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option OMRON 3G2A5-AD003. When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Specification: three phase 400V.
Power: 1.5KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling: forced air cooling.
Weight: 1.2kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage aand the most close to the market elements 3G2A5-AD003.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice.

Related supply information