C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD003(3G2A5-AD003).
Input: 2 pts.
Specification: 0~+5V.Short protection for 10-pin terminal block (package of 10 covers). 12 pts.
C500-AS Special I/O Unit ASCII BASIC UNIT C500-ASC01.Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; PNP;
With Short-circuit and,
Disconnected Line DDetection C500-ASC01.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet C500-ASC01.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site C500-ASC01.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Compact Connectors.
Specifications: Inputs/Outputs; 1 input/1 output; NPN.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery OMRON C500-ASC01.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price OMRON C500-ASC01.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. 4 thermocouple inputsModel: C200H-DA003.
Input points: 8.
Voltage input: 1 to 5V or 10 to 10 V or –10 to 10 V OMRON C500-ASC01.Supply voltage: 24 VDC
Operating voltage range: 20.4 to 28.8 VDC
Power consumption: 100 W max.
Output capacity: 12 A, 5 VDCPower supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 6 points.
Outputs points: 4 points.Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Miicrosecond Throughput:
Models with Direct Conversion Join the Lineup C500-ASC01.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.