Model : CVM1D-BI102.
10-slot.The initial configuration of the G language unit in the industry due to the use of G language,
Complex processing procedures do not need to be able to make the ladder diagram.
The realization of the first 1 axis simultaneous control of 4 axis simultaneous control in the industry is due to the multi task function,
Can be executed at the same ttime or the 2 axis simultaneous control of 4 axes, and then can achieve the 4 axis independent control, etc CS1W-CLK13.
Up to 8 units can be installed CVM1 8 units can be installed 1 units, can control up to 32 axes CS1W-CLK13.
Applicable to ABS encoder by standard,
Applicable to the ABS type (absolute output) encoder, so after the emergency stop, no need to search for the origin, etc..
S curve also according to the standard configuration plus deceleration curve, in addition to the trapezoidal outside,
Also configured to suppress the mechanical vibration of the S shape curve CS1W-CLK13.
Program login maximum of up to 100
G language can be programmed with the MC support software G
Unit classifi cation: CS1 CPU Bus Unit OMRON CS1W-CLK13.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring H-PCF cable;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units) OMRON CS1W-CLK13.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words OMRON CS1W-CLK13.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Name: Two-tier Screw Terminal Block.
Specifications: Inputs; 8 inputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1W-CLK13.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.