C500-IM I/O Unit INPUT MODULE 16POINT 24VAC/DC C500-IM211(3G2A5-IM211).
AC/DC12-24V 10mA。Analog inputs: 4 points.
Model : CV500-CPU01-EV1.
SFC / Ladder 512 (with RAM30K words, the top internal link).Unit classification: CJ1 CPU Bus Unit.
Specifications:Equipped with Master,
and Slave functionality CV500-CPU01-EV1.
Controls for up to 32,000 points perr Master.
Communications:Remote I/O Communications,
Master (fixed allocations or user-set,
allocations) Remote I/O Communications,
Slave (fixed allocations or user-set,
allocations) Message communica29A; 24V,-- CV500-CPU01-EV1.
Smallest in the Industry!
A DeviceNet Unit for the,
CJ Series that Boasts Industry-leading,
Performance and Functions.
Model: C500-CN512N.
Cable length 50cm.
CV Series C Series Expansion ← → I / O device CPU Connecting cable(Vertical-wired)Product name: AC Power Supply Unit CV500-CPU01-EV1.
Power supply voltage: 100 to 240VAC.
Output capacity: 5-VDC output capacity, 5A;
24-VDC output capacity, 0.8A;
Total power consumption, 25w.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecast monitor, Yes OMRON CV500-CPU01-EV1.
Standards: UC1, N, L, CE.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement.
notification function for easy,
maintenance OMRON CV500-CPU01-EV1.
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options OMRON CV500-CPU01-EV1. Model: C500-CE241.
Connection : Soldered.
FCN-361J024-AU Connector
FCN-360C024-J2 Connector coverNumber of outputs: 32 pts.
Max. switch-ing capacity: 0.5 A at 24 V DC.
External connector: Connector.
Weight: 210 g max.Model : C500-PRW06.
C500-OD I/O Unit Transistor Output 16 pts C500-OD411(3G2A5-OD411).
DC12~48V 1A.Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems CV500-CPU01-EV1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.