CJ1W-OC211 OMRON CJ1W-OC211 Output Units


Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System,
or Single CPU System;
Duplexing, Not supported;
Online Replacement, Not supported;
Mounting Backplane,CPU Backplane;
Connecting Cable,
Long-distance Connecting Cable CJ1W-OC211.
Current consumption: 5V system, 0.92A;
26V sysstem, --.
Standards: U, C, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CJ1W-OC211. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector PNP outputs (pulses).
No CJ1W-OC211. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output OMRON CJ1W-OC211.
Unit type: CJ1 Basic I/O Units.
Product name: Relay Contact Output Units.
Specifications: Output type , --;
I/O points, 16 inputs;
Maximum switching capacity, 250VAC/24VDC, 2A;
Commons, 16 points, 1 common;
External connection, Removable terminal block OMRON CJ1W-OC211.
No. of words allocated: 1 word.
Current consumption: 5V, 0.11A; 24V, 0.096A max.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications OMRON CJ1W-OC211.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
Model: CPM2A-60CDR-D. Power supply: DC power supply.
Output type: Relay.
Inputs points: 36 points.
Outputs points: 24 points.Name: MIL Connectors.
Specifications: Inputs/Outputs;
16 inputs/16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CJ1W-OC211.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.