Output method: Transistor sourcing.
Inputs: ---.
Outputs: 16.Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 5V.
Output current: 3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device .
Built in support for determining the abnormal causes of the new under voltage detection function
PYDM-14SB
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage PYDM-14SB.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards PYDM-14SB. (200V input)
High harmonic current limit: EN61000-3-2 . (except for type 15/30W)
Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Roller lever *1, Low-torque.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV sttatus display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV PYDM-14SB.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput PYDM-14SB.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
PYDM-14SB Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=PYDM-14SB&select=5