Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use S82J-02512D.
Event input points: -.
Transfer output: transfer output (special terminal)
S82J-02512D
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance S82J-02512D.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation S82J-02512D.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc . , can be a key operation. Type: slotted screw type.
IO points (number of poles): 34.
The PLC connection type and the rich polar number of PLC are specially connected.
PLC connection type for the use of OMRON and MITSUBISHI motor,
PLC (plant) production of specialized connection wiring mode, to facilitate the confirmation signal configuration.
In addition, the terminal table record PLC address on the label.
Universal type for a variety of connectors, the number of species.
Connection with cross recessed screws, slotted screw type and insertion type.
DIN guide rail and screw can be used to install.
Terminal arrangement fully considers the maneuverability, makes the connection operation become easy and simple.
The operability of the plug-in terminal can be improved (XW2F comparison of the company).
Number of beams: 68.
Protective height: 2040mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module ((PDM) makes it easy,
to set functions S82J-02512D.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Lightt CCurtain functions S82J-02512D.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
S82J-02512D Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=S82J-02512D&select=5